Phone: (601)354-2756


Main => Motors Electric =>AC Motors =>Medium Voltage

Teco-Westinghouse JH17506 HP: 1750 Volts: 2300/4160 RPM: 1200
VIN#: 1194450509
Qty on hand Qty on hand: Stock
Share this Info
Print this Page

Condition:New
Catalog Number:JH17506
Manufacturer:Teco-Westinghouse
Enclosure:Totally Enclosed Fan Cooled (IP54 Rating)
Frame:560C
Hertz:60
HP:1750
Model No.:JH17506
Mounting:F1 Mounted
Phase:3
RPM:1200
Voltage:2300/4160

Notes:

  • For other voltages, please refer to factory.

GLOBAL-PLUS
TYPE AEJHTK

Applications:

FL Eff: 96.2
FL Pf: 86.0
FL Amps (2300V): 396
Approx. Shipping WT.lbs: 18,000



  • Pumps
  • Fans & Blowers
  • Compressors
  • 800 – 2000 HP
  • 1800, 1200, 900 RPM
  • Totally Enclosed Fan Cooled (IP54 Rating)
  • Premium Efficient Design
  • 36 Month Warranty from Date of Manufacture
  • 3 Phase, 60 Hz, 2300 / 4160V
  • Standard with 120V Space Heaters Terminated in Separate Auxiliary Box
    Standard with 100 Ohm Platinum Stator RTDs, 2 per Phase, Terminated in Separate Auxiliary Box
  • 1.15 Service Factor – Continuous
  • Class F Thermalastic® Epoxy Insulation
  • Class B Temperature Rise
  • NEMA Design B Torques
  • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrances - F1 Mounted.
  • Designed for 40°C Ambient Temperature - Note (1)
  • Designed for 3300 ft. Elevation - Note (2)
  • Cast Iron Frame, End Bells, and Conduit Box
  • Rolled Steel Fan Cover
  • 1045 Carbon Steel Shaft
  • Copper / Copper Alloy Rotor Construction
  • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
  • Paint Color: Blue Gray – Munsell 7.5BG 4/2
    Vacuum De-Gassed Regreasable Ball Bearings Using Polyrex EM Grease
  • Insulated Non – Drive-End Bearing on 500 Frames and Larger
  • Labyrinth Type Metal Grease Flinger on Both Ends
  • Dust Flinger on Both Ends
  • Cast Iron Inner and Outer Bearing Caps
  • Grounding Terminal Inside Main Box and on Motor Foot
  • Stainless Steel Nameplate
  • Suitable for Use on a VFD - Notes (3)(4)(5)(6)
  • 6 Leads

Extras / Options:

Notes:

  1. Please consult factory for suitability in higher ambients.
  2. Please consult factory for suitability in higher elevations.
  3. Service factor is 1.0 when motor is used on a VFD.
  4. An isolation transformer or other method of mitigating common mode voltages from motor terminals must be utilized.
  5. Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD.
  6. Please contact TWMC for variable and constant torque speed ranges.

Error Occurred While Processing Request

Error Occurred While Processing Request

Error Diagnostic Information

ODBC Error Code = 37000 (Syntax error or access violation)

[Microsoft][ODBC SQL Server Driver][SQL Server]Could not allocate space for object 'CDATA' in database 'CFXClient' because the 'PRIMARY' filegroup is full.

Date/Time: 10/17/17 19:21:43
Browser: CCBot/2.0 (http://commoncrawl.org/faq/)
Remote Address: 107.22.126.144
Query String: item=1194450509