Phone: (601)354-2756


Main => Motors Electric =>AC Motors => Medium Voltage
 
1 2 3 4 5 6 7 8 9 10
Search Medium Voltage
Mfg  
Phase  
HP  
RPM  
Voltage  
Enclosure  
Frame  
Catalog #  
Teco-Westinghouse 3 800 3600 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 6808A KG8002
Teco-Westinghouse 3 800 1800 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 6808B KG8004
Teco-Westinghouse 3 800 1200 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 6808C KG8006R
Teco-Westinghouse 3 800 1800 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 6808B K8004
GE 3 800 3600 2300/4000 WII 5011LS S3414
GE 3 800 3600 2300/4000 WPI 5013ST E9970
GE 3 800 1800 2300/4000 WPI 5013S E9979
Teco-Westinghouse 3 800 900 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 450C JH08008
Teco-Westinghouse 3 900 1200 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 450C JH09006
Teco-Westinghouse 3 900 900 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 500C JH09008
GE 3 900 3600 2300/4000 WPI 5013ST E9972
GE 3 900 1800 2300/4000 WPI 5013S E9980
Teco-Westinghouse 3 900 1800 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 6808B KG9004
Teco-Westinghouse 3 900 3600 2300/4160 WPI 5810A P9002
Teco-Westinghouse 3 900 1800 2300/4160 WPI 5810B P9004
Teco-Westinghouse 3 900 1200 2300/4160 WPI 6806C P9006R
Teco-Westinghouse 3 1000 3600 2300/4160 WPI 5810A P10002
Teco-Westinghouse 3 1000 1800 2300/4160 WPI 6806B P10004
Teco-Westinghouse 3 1000 1200 2300/4160 WPI 6808C P10006R
Teco-Westinghouse 3 1000 1800 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 450C JH10004
Teco-Westinghouse 3 1000 1200 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 500C JH10006
Teco-Westinghouse 3 1000 900 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 500C JH10008
Teco-Westinghouse 3 1250 1800 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 500C JH12504
Teco-Westinghouse 3 1250 1200 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 500C JH12506
Teco-Westinghouse 3 1250 900 2300/4160 Totally Enclosed Fan Cooled (IP54 Rating) 560C JH12508
Teco-Westinghouse 3 1250 1800 2300/4160 WPI 6808B P12504
Search Medium Voltage
1 2 3 4 5 6 7 8 9 10
Page 10 of 11

Error Occurred While Processing Request

Error Occurred While Processing Request

Error Diagnostic Information

ODBC Error Code = 37000 (Syntax error or access violation)

[Microsoft][ODBC SQL Server Driver][SQL Server]Could not allocate space for object 'CDATA' in database 'CFXClient' because the 'PRIMARY' filegroup is full.

Date/Time: 10/17/17 13:49:22
Browser: CCBot/2.0 (http://commoncrawl.org/faq/)
Remote Address: 54.92.141.211
Query String: category=1172463497&cfield=MFGMain&sortf=HP&sortm=ASC&sr=226